Search by Model
View Mode:
SHEET
:
TAB
Print Product Info
Overview
Residential or Commercial
Residential
Installation Location
Indoor Only
Exhaust Type
2-pipe Direct Vent
Max Flow Rate
11.1 GPM
Flow Rate @ 50°F Rise
8.4 GPM
Flow Rate @ 80°F Rise
5.3 GPM
Temperature Range
100°F - 180°F
Production Status
Discontinued
Condensing
No
Minimum Activation Flow Rate
0.5
Water Quality
Treatment May Be Necessary
Freeze Protection
Yes
Freeze Protection Rating - Indoor Temp
-30°F
Freeze Protection Rating - Outdoor Temp
N/A
Recirculation Compatible ?
Yes
New Generation Model Number
N/A
Previous Name
N-0931M-DV-LP
Available Temperature Settings (with remote)
100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 160, 170, 180°F
Default Temperature Setting (without remote)
120°F
Default Temperature Program Setting Options (without remote)
120, 130, 140, 180°F
Production Date Range
05/2007 - Present
Technical Specs & Installation
Min Gas Input (Btu)
11000
Max Gas Input (Btu)
250000
Height (in)
24.2
Width (in)
18.3
Depth (in)
9.4
Weight (lbs)
62
Thermal Efficiency
84%
Energy Factor
N/A
Afue
N/A
Quick-Connect Compatible?
Yes
Cold Water Connection Size (in)
3/4
Hot Water Connection Size (in)
3/4
Gas Connection Size (in)
3/4
Power Supply
120 VAC (60 Hz)
Current Draw (A)
1.341
Exhaust Vent Diameter Requirements
4"
Exhaust Vent Material Requirements
Category III Stainless Steel
Max Vent Length with 1 elbow
57’
Vent Termination Clearances to Any Building Opening (ft)
Below = 1’, Side = 1’, or Above = 1’
Gas Supply Pressure Range
10.5 - 14" WC
Min Gas Line Size
3/4" up to 40’
Water Pressure Rating (psi)
15-150
Case Clearances (in)
Top = 12", Front = 4", Sides = 2", Back = 0"
Combustion Air Requirements - using Indoor Air
N/A
Combustion Air Requirements - using Outdoor Air
N/A
Head Loss at 2 gpm
4.62 ft of head
Cold Connection Height
2.2"
Power Consumption w/out Freeze Prevention
100 Watts
Power Consumption w/Freeze Prevention
161 Watts
Flow Meter Alarm
Yes
Service Reminder
No
Condensate Handling Method?
N/A
Noise Rating (dB)
Less than 60 dB
Tested to UL Computer Controlled Safety Standards
Yes
Flame Sensor
Yes
High Limit Switch
Yes
Lightning Protection
Yes
Overheat Cutoff Fuse)
Yes
Temperature Lockout
Yes
Ignition Type
Direct Electronic
Case Material
Durable Steel Casing with Polyester Coating
Color/Finish
Beige
Flue Collar Material
Stainless Steel
Primary Heat Exchanger Material
Copper
Secondary Heat Exchanger Material
N/A
Mounting Type
Wall Hung
Package Contents
Tapping Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual
Water Holding Capacity
0.3 gallons
Accessories
Keypad/Thermostat Display
Included
Compatible Remote Controller Part #
RC-7649M
Isolator Valve Part #
IK-WV-200-1-xx
Freeze Protection
Yes
Freeze Protection Kit Accessory
Outdoor Vent Cap Part #
N/A
Pipe Cover Part #
PC-3S
Recess Box Part #
N/A
High Elevation Adjustment
Yes
Quick-Connect Cord Part #
QC-1
System Controller Compatible?
No
System Controller Part #
N/A
Remote Controller Cord
Included
Compatible Remote Controller Cord Part #
RC-CORD10
Power Cord
Included in box
Approvals
ENERGY STAR® Qualified
No
CSA
Yes
Mobile Home
Yes
NSF
Yes
SCAQMD (20 ppm)
No
SCAQMD (55 ppm)
Yes
UPC
No
Energy Guide - Est. Yearly Energy Use
198 gallons
Energy Guide - Est. Yearly Operating Cost
$370
UPC Low Lead
Yes
ASME (HLW)
No
ASME (H)
No
ASME (NB)
No
Warranty
Heat Exchanger Warranty (w/out Recirculation)
12 Years
Heat Exchanger Warranty (w/Recirculation)
12 Yrs. w/ Aquastat
Parts Warranty
5 Years
Labor Warranty
1 Year