SHEET
:
TAB

Overview

Residential or Commercial Residential
Installation Location Indoor or Outdoor with Vent Cap
Exhaust Type Single Vent
Max Flow Rate 8.4 GPM
Flow Rate @ 50°F Rise 7.8 GPM
Flow Rate @ 80°F Rise 4.8 GPM
Temperature Range 100°F - 180°F
Production Status Discontinued
Condensing No
Minimum Activation Flow Rate 0.7
Water Quality Treatment May Be Necessary
Freeze Protection Yes
Freeze Protection Rating - Indoor Temp 5°F
Freeze Protection Rating - Outdoor Temp 5°F
Recirculation Compatible ? Yes
New Generation Model Number NR111-SV-NG
Previous Name N/A
Available Temperature Settings (with remote) 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 160, 170, 180°F
Default Temperature Setting (without remote) 120°F
Default Temperature Program Setting Options (without remote) 120, 130, 140, 180°F
Production Date Range 08/2004 - 03/2007

Technical Specs & Installation

Min Gas Input (Btu) 21000
Max Gas Input (Btu) 236000
Height (in) 24.2
Width (in) 18.3
Depth (in) 9.4
Weight (lbs) 63
Thermal Efficiency N/A
Energy Factor N/A
Afue N/A
Quick-Connect Compatible? Yes
Cold Water Connection Size (in) 3/4
Hot Water Connection Size (in) 3/4
Gas Connection Size (in) 3/4
Power Supply 120 VAC (60 Hz)
Current Draw (A) 1.125
Exhaust Vent Diameter Requirements 4"
Exhaust Vent Material Requirements Category III Stainless Steel
Max Vent Length with 1 elbow 39’
Vent Termination Clearances to Any Building Opening (ft) Below = 4’, Side = 4’, or Above = 1’
Gas Supply Pressure Range 4 - 10.5" WC
Min Gas Line Size 3/4" up to 20’
Water Pressure Rating (psi) 15-150
Case Clearances (in) Top = 12", Front = 4", Sides = 2", Back = 0"
Combustion Air Requirements - using Indoor Air 236 in²
Combustion Air Requirements - using Outdoor Air 100 in²
Head Loss at 2 gpm 4.62 ft of head
Cold Connection Height 2.2"
Power Consumption w/out Freeze Prevention 80 Watts
Power Consumption w/Freeze Prevention 135 Watts
Flow Meter Alarm Yes
Service Reminder No
Condensate Handling Method? N/A
Noise Rating (dB) Less than 60 dB
Tested to UL Computer Controlled Safety Standards Yes
Flame Sensor Yes
High Limit Switch Yes
Lightning Protection Yes
Overheat Cutoff Fuse) Yes
Temperature Lockout No
Ignition Type Direct Electronic
Case Material Durable Steel Casing with Polyester Coating
Color/Finish Beige
Flue Collar Material Stainless Steel
Primary Heat Exchanger Material Copper
Secondary Heat Exchanger Material N/A
Mounting Type Wall Hung
Package Contents Tapping Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual
Water Holding Capacity 0.3 gallons

Accessories

Keypad/Thermostat Display Included
Compatible Remote Controller Part # RC-7646M-2
Isolator Valve Part # IK-WV-200-1-xx
Freeze Protection Yes
Freeze Protection Kit Accessory
Outdoor Vent Cap Part # VC-4
Pipe Cover Part # PC-084
Recess Box Part # RB-3
High Elevation Adjustment Yes
Quick-Connect Cord Part # QC-1
System Controller Compatible? Yes
System Controller Part # SC-201-6M, -12M, -24M
Remote Controller Cord Included
Compatible Remote Controller Cord Part # RC-CORD10
Power Cord Not included

Approvals

ENERGY STAR® Qualified No
CSA Yes
Mobile Home No
NSF Yes
SCAQMD (20 ppm) No
SCAQMD (55 ppm) Yes
UPC No
Energy Guide - Est. Yearly Energy Use 203 therms
Energy Guide - Est. Yearly Operating Cost $185
UPC Low Lead Yes
ASME (HLW) No
ASME (H) No
ASME (NB) No

Warranty

Heat Exchanger Warranty (w/out Recirculation) 10 Years
Heat Exchanger Warranty (w/Recirculation) 3 Years
Parts Warranty 3 Years
Labor Warranty 1 Year