Min Gas Input (Btu) | 18,000 | |
Max Gas Input (Btu) | 199,900 | |
Height (in) | 27 | |
Width (in) | 18.5 | |
Depth (in) | 12.8 |  |
Weight (lbs) | 81 | |
Thermal Efficiency | 96% | |
Energy Factor | UEF 0.96 | |
Afue | N/A | |
Quick-Connect Compatible? | Yes |  |
Cold Water Connection Size (in) | 3/4 | |
Hot Water Connection Size (in) | 3/4 | |
Gas Connection Size (in) | 3/4 | |
Power Supply | 120 VAC | |
Current Draw (A) | 2.55 | |
Exhaust Vent Diameter Requirements | 2" or 3" | |
Exhaust Vent Material Requirements | PVC or CPVC | |
Max Vent Length with 1 elbow | 65’ with 2" or 150’ with 3" |  |
Vent Termination Clearances to Any Building Opening (ft) | Below = 1’, Side = 1’, or Above = 1’ |  |
Gas Supply Pressure Range | 8-14" WC | |
Min Gas Line Size | 3/4" up to 59’ | |
Water Pressure Rating (psi) | 15-150 | |
Case Clearances (in) | Top = 12", Front = 4", Sides = 3", Back = 0" |  |
Combustion Air Requirements - using Indoor Air | 200 in² (Only if SV conversion) | |